date:Aug 06, 2012
s) for 316 and 304 steel, or the higher standards set by Ecolab (see below Fig 3 ):
Fig 3. Corrosion standards
The data clearly (Fig 4) indicates that under the most extreme temperature of 82oC and after two weeks), the amount of corrosion caused on SS coupons is less than the external standards (4 MPY, 10 MPY) and the standards set by Ecolab (1 MPY). Given these results, give great confidence to users of the product when the product is used at the lower recommended temperatures of 45-50oC.