When are Organic Catalysts Treatments Useful?
date:Dec 11, 2012
WWTP, USA:


3.8 MLD, residential/industrial wastewater


52-week trial results


2ppm bio-catalyst


28% reduction in wasted sludge


16% reduction in BOD (34% during peaks)


Odour elimination